1) What parameter(s) is / are checked using the commissioning tests?
a. Turbine speed
b. Condenser vacuum
c. Turbine governor valve opening
d. Only b and c
e. All of these
|
Answer
Explanation
|
ANSWER: All of these
Explanation: No explanation is available for this question!
|
|
2) Which among the following sequence is correct for a synchronous generator?
a. I” d > I d > I’ d
b. I d > I’ d > I” d
c. I” d > I’ d > I d
d. I d > I” d > I’ d
|
Answer
Explanation
|
ANSWER: I”d > I’d > Id
Explanation: No explanation is available for this question!
|
|
3) What is filled in between fixed and rotating parts of a cryogenic generator?
a. Dry air
b. Hydrogen
c. Oxygen
d. None of these
|
Answer
Explanation
|
ANSWER: Hydrogen
Explanation: No explanation is available for this question!
|
|
4) Which power factor condition is not suitable for the operation of synchronous generator?
a. Leading power factor
b. Lagging power factor
c. Both (A) and (B)
d. None of these
|
Answer
Explanation
|
ANSWER: Leading power factor
Explanation: No explanation is available for this question!
|
|
5) What should be the frequency of the incoming machine while the machine is synchronising to operate in parallel?
a. Approximately 1 / 10 cycle less than the bus frequency
b. Approximately 1 / 10 cycle higher than the bus frequency
c. Approximately 1 / 100 cycle less than the bus frequency
d. Approximately 1 / 100 cycle higher than the bus frequency
|
Answer
Explanation
|
ANSWER: Approximately 1 / 10 cycle higher than the bus frequency
Explanation: No explanation is available for this question!
|
|
6) Arrange the following according to the starting procedure of a synchronous Generator?
i. Start turbine auxiliaries ii. Start boiler iii. Roll the turbine iv. Start the boiler auxiliaries v. Keep the units as a spinning reserve
a. i, iii, v, iv, ii
b. i, iv, ii, iii, v
c. iv, i, ii, iii, v
d. iii, i, v, iv, ii
|
Answer
Explanation
|
ANSWER: iv, i, ii, iii, v
Explanation: No explanation is available for this question!
|
|
7) Which among these is the most significant for the operation of synchronous generator?
a. Frequency
b. Load
c. Terminal voltage
d. Only (a) and (b)
e. All of these
|
Answer
Explanation
|
ANSWER: All of these
Explanation: No explanation is available for this question!
|
|
8) Which type of rotor is used by Hydro Generators?
a. Salient pole
b. Cylindrical rotor
c. Both (A) and (B)
d. None of these
|
Answer
Explanation
|
ANSWER: Salient pole
Explanation: No explanation is available for this question!
|
|
9) Which type of cooling system is preferred for turbo alternators?
a. Forced air
b. Hydrogen
c. Water cooled
d. Only (b) & (c)
e. All of these
|
Answer
Explanation
|
ANSWER: All of these
Explanation: No explanation is available for this question!
|
|
10) What is the maximum rated output for an engine driven synchronous generator?
a. 10 MW
b. 20 MW
c. 50 MW
d. 100 MW
|
Answer
Explanation
|
ANSWER: 20 MW
Explanation: No explanation is available for this question!
|
|